Article(electronic)January 1, 2009

A New Design Method for Industrial Portal Frames in Fire

In: Acta polytechnica: journal of advanced engineering, Volume 49, Issue 1

Checking availability at your location

Abstract

Industrial portal frames near to other buildings must keep their vertical walls standing in fire in order to prevent fire spread. A recently developed analysis, implemented in the program Vulcan, using a combination of static and dynamic solvers, has shown that the strong base connections recommended by the current design method may not always lead to conservative design. A second-phase failure mechanism observed in numerical modelling, and the critical temperature at which final run-away collapse occurs, may be higher than the temperature at which the roof frame initially loses its stability, because a re-stabilisation often happens. A new method for estimating critical temperatures of portal frames in fire, using these two failure mechanisms, is presented. Numerical tests on typical industrial frames are used to calibrate this new method.

Publisher

Czech Technical University in Prague - Central Library

ISSN: 1805-2363

DOI

10.14311/1093

Report Issue

If you have problems with the access to a found title, you can use this form to contact us. You can also use this form to write to us if you have noticed any errors in the title display.