Article(electronic)October 14, 2015

A septic tank‐UASB combined system for domestic wastewater treatment: a pilot test

In: Water and environment journal, Volume 29, Issue 4, p. 558-565

Checking availability at your location

Abstract

AbstractA 250 L and a 550 L pilot scale Up‐Flow Anaerobic Sludge Blanket (UASB) reactors having different reactor height were fed septic tank effluents and operated at ambient temperatures of 0°C to 30°C. Both UASB reactors were fed intermittently at least 8 times per Hydraulic Retention Time (HRT) and the performance was monitored at 4d and 1d HRT. The removal efficiencies of Total Suspended Solid (TSS) and Total Chemical Oxygen Demand (CODt) were about 59–68% and 54–59%, respectively, for both reactors at both HRT. The TSS and CODt removal efficiencies of Septic tank – UASB combined system were above 80% for both HRTs tested. The average biogas yields were almost same at 4d and 1d HRT, representing 31(±3)% of influent CODt. The nitrogen and phosphorous removal efficiency was an average 20–30%. The tested system can become a suitable low cost yet effective option.

Languages

English

Publisher

Wiley

ISSN: 1747-6593

DOI

10.1111/wej.12154

Report Issue

If you have problems with the access to a found title, you can use this form to contact us. You can also use this form to write to us if you have noticed any errors in the title display.