Funding: The authors acknowledged the support granted by the Instituto de Salud Carlos III (ISCIII) (ISCIII/FIS-PI 12/01815) Spanish Government ; BACKGROUND: The diagnosis of ventilator-associated pneumonia (VAP) is challenging. An important aspect to improve outcome is early recognition of VAP and the initiation of the appropriate empirical treatment. We hypothesized that biological markers in plasma can rule out VAP at the moment of clinical suspicion and could rule in VAP before the diagnosis can be made clinically. METHODS: In this prospective study, patients with VAP (n = 24, microbiology confirmed) were compared to controls (n = 19) with a similar duration of mechanical ventilation. Blood samples from the day of VAP diagnosis and 1 and 3 days before were analyzed with a multiplex array for markers of inflammation, coagulation, and apoptosis. The best biomarker combination was selected and the diagnostic accuracy was given by the area under the receiver operating characteristic curve (ROC-AUC). RESULTS: TNF-receptor 1 (TNFRI) and granulocyte colony-stimulating factor (GCSF) were selected as optimal biomarkers at the day of VAP diagnosis, which resulted in a ROC-AUC of 0.96, with excellent sensitivity. Three days before the diagnosis TNFRI and plasminogen activator inhibitor-1 (PAI-1) levels in plasma predicted VAP with a ROC-AUC of 0.79. The slope of IL-10 and PAI-1 resulted in a ROC-AUC of 0.77. These biomarkers improved the classification of the clinical pulmonary infection score when combined. CONCLUSIONS: Concentration of TNFRI and PAI-1 and the slope of PAI-1 and IL-10 may be used to predict the development of VAP as early as 3 days before the diagnosis made clinically. TNFRI and GCSF may be used to exclude VAP at the moment of clinical suspicion. Especially TNFRI seems to be a promising marker for the prediction and diagnosis of VAP. ; publishersversion ; published
Funding The project was funded by the European Union FP7 Marie Curie Actions, under the Industry-Academia Partnerships and Pathways (IAPP) programme (MC-IAPP BreathDx 611951). WA, TF, PD and SJF were supported by the NIHR Manchester Biochemical Research Centre. ; BACKGROUND: Ventilator-associated pneumonia (VAP) is associated with high morbidity and health care costs, yet diagnosis remains a challenge. Analysis of airway microbiota by amplicon sequencing provides a possible solution, as pneumonia is characterised by a disruption of the microbiome. However, studies evaluating the diagnostic capabilities of microbiome analysis are limited, with a lack of alignment on possible biomarkers. Using bronchoalveolar lavage fluid (BALF) from ventilated adult patients suspected of VAP, we aimed to explore how key characteristics of the microbiome differ between patients with positive and negative BALF cultures and whether any differences could have a clinically relevant role. METHODS: BALF from patients suspected of VAP was analysed using 16s rRNA sequencing in order to: (1) differentiate between patients with and without a positive culture; (2) determine if there was any association between microbiome diversity and local inflammatory response; and (3) correctly identify pathogens detected by conventional culture. RESULTS: Thirty-seven of 90 ICU patients with suspected VAP had positive cultures. Patients with a positive culture had significant microbiome dysbiosis with reduced alpha diversity. However, gross compositional variance was not strongly associated with culture positivity (AUROCC range 0.66-0.71). Patients with a positive culture had a significantly higher relative abundance of pathogenic bacteria compared to those without [0.45 (IQR 0.10-0.84), 0.02 (IQR 0.004-0.09), respectively], and an increased interleukin (IL)-1β was associated with reduced species evenness (rs = - 0.33, p < 0.01) and increased pathogenic bacteria presence (rs = 0.28, p = 0.013). Untargeted 16s rRNA pathogen detection was limited by ...
In: Aman , J , Duijvelaar , E , Botros , L , Kianzad , A , Schippers , J R , Smeele , P J , Azhang , S , Bartelink , I H , Bayoumy , A A , Bet , P M , Boersma , W , Bonta , P I , Boomars , K A T , Bos , L D J , van Bragt , J J M H , Braunstahl , G-J , Celant , L R , Eger , K A B , Geelhoed , J J M , van Glabbeek , Y L E , Grotjohan , H P , Hagens , L A , Happe , C M , Hazes , B D , Heunks , L M A , van den Heuvel , M , Hoefsloot , W , Hoek , R J A , Hoekstra , R , Hofstee , H M A , Juffermans , N P , Kemper , E M , Kos , R , Kunst , P W A , Lammers , A , van der Lee , I , van der Lee , E L , Maitland-van der Zee , A-H , Mau Asam , P F M , Mieras , A , Muller , M , Neefjes , L , Nossent , E J , Oswald , L M A , Overbeek , M J , Pamplona , C , Paternotte , N , Pronk , N , de Raaf , M A , van Raaij , B F M , Reijrink , M , Schultz , M J , Serpa Neto , A , Slob , E M , Smeenk , F W J M , Smit , M R , Smits , A J , Stalenhoef , J E , Tuinman , P R , Vanhove , A L E M , Wessels , J N , van Wezenbeek , J C C , Vonk Noordegraaf , A , de Man , F S & Bogaard , H J 2021 , ' Imatinib in patients with severe COVID-19 : a randomised, double-blind, placebo-controlled, clinical trial ' , Lancet respiratory medicine , vol. 9 , no. 9 , pp. 957-968 . https://doi.org/10.1016/S2213-2600(21)00237-X , https://doi.org/10.1016/S2213-2600(21)00237-X
BACKGROUND: The major complication of COVID-19 is hypoxaemic respiratory failure from capillary leak and alveolar oedema. Experimental and early clinical data suggest that the tyrosine-kinase inhibitor imatinib reverses pulmonary capillary leak. METHODS: This randomised, double-blind, placebo-controlled, clinical trial was done at 13 academic and non-academic teaching hospitals in the Netherlands. Hospitalised patients (aged ≥18 years) with COVID-19, as confirmed by an RT-PCR test for SARS-CoV-2, requiring supplemental oxygen to maintain a peripheral oxygen saturation of greater than 94% were eligible. Patients were excluded if they had severe pre-existing pulmonary disease, had pre-existing heart failure, had undergone active treatment of a haematological or non-haematological malignancy in the previous 12 months, had cytopenia, or were receiving concomitant treatment with medication known to strongly interact with imatinib. Patients were randomly assigned (1:1) to receive either oral imatinib, given as a loading dose of 800 mg on day 0 followed by 400 mg daily on days 1-9, or placebo. Randomisation was done with a computer-based clinical data management platform with variable block sizes (containing two, four, or six patients), stratified by study site. The primary outcome was time to discontinuation of mechanical ventilation and supplemental oxygen for more than 48 consecutive hours, while being alive during a 28-day period. Secondary outcomes included safety, mortality at 28 days, and the need for invasive mechanical ventilation. All efficacy and safety analyses were done in all randomised patients who had received at least one dose of study medication (modified intention-to-treat population). This study is registered with the EU Clinical Trials Register (EudraCT 2020-001236-10). FINDINGS: Between March 31, 2020, and Jan 4, 2021, 805 patients were screened, of whom 400 were eligible and randomly assigned to the imatinib group (n=204) or the placebo group (n=196). A total of 385 (96%) patients (median age 64 years [IQR 56-73]) received at least one dose of study medication and were included in the modified intention-to-treat population. Time to discontinuation of ventilation and supplemental oxygen for more than 48 h was not significantly different between the two groups (unadjusted hazard ratio [HR] 0·95 [95% CI 0·76-1·20]). At day 28, 15 (8%) of 197 patients had died in the imatinib group compared with 27 (14%) of 188 patients in the placebo group (unadjusted HR 0·51 [0·27-0·95]). After adjusting for baseline imbalances between the two groups (sex, obesity, diabetes, and cardiovascular disease) the HR for mortality was 0·52 (95% CI 0·26-1·05). The HR for mechanical ventilation in the imatinib group compared with the placebo group was 1·07 (0·63-1·80; p=0·81). The median duration of invasive mechanical ventilation was 7 days (IQR 3-13) in the imatinib group compared with 12 days (6-20) in the placebo group (p=0·0080). 91 (46%) of 197 patients in the imatinib group and 82 (44%) of 188 patients in the placebo group had at least one grade 3 or higher adverse event. The safety evaluation revealed no imatinib-associated adverse events. INTERPRETATION: The study failed to meet its primary outcome, as imatinib did not reduce the time to discontinuation of ventilation and supplemental oxygen for more than 48 consecutive hours in patients with COVID-19 requiring supplemental oxygen. The observed effects on survival (although attenuated after adjustment for baseline imbalances) and duration of mechanical ventilation suggest that imatinib might confer clinical benefit in hospitalised patients with COVID-19, but further studies are required to validate these findings. FUNDING: Amsterdam Medical Center Foundation, Nederlandse Organisatie voor Wetenschappelijk Onderzoek/ZonMW, and the European Union Innovative Medicines Initiative 2.