Open Access BASE2020

Impact of Using Different Levels of Threshold-Based Artefact Correction on the Quantification of Heart Rate Variability in Three Independent Human Cohorts

Abstract

The following are available online at https://www.mdpi.com/2077-0383/9/2/325/s1, Figure S1: Example of a visual inspection of a R-R signal to find possible artefacts or premature contractions across Kubios filters; Figures S2 and S3: Differences on the Heart Rate Variability (HRV) time- and frequency-domains parameters respectively without considering the Very Strong filter; Figure S4: Differences between cohorts on the SDNN using different Kubios filters; Figure S5: Differences between cohorts on the pNN50 using different Kubios filters; and Figure S6: Differences between cohorts on the HF using different Kubios filters. ; Juan M.A. Alcantara, Abel Plaza-Florido, Jairo H. Migueles, Guillermo Sanchez-Delgado and Francisco J. Amaro-Gahete are supported by the Spanish Ministry of Education, Culture and Sport (FPU15/04059, FPU16/02760, FPU15/02645, FPU13/04365 and FPU14/04172 respectively). Guillermo Sanchez-Delgado is supported by the University of Granada Plan Propio de Investigación 2018 (Programa Contratos-Puente and Programa Perfeccionamiento de Docotres). Francisco J. Amaro-Gahete is supported by the University of Granada Plan Propio de Investigación 2019 (Programa Contratos-Puente). Guillermo Sanchez-Delgado and Borja Martinez-Tellez are supported by individual postdoctoral grants from the Fundación Alfonso Martin Escudero. ; Heart rate variability (HRV) is a non-invasive indicator of autonomic nervous system function. HRV recordings show artefacts due to technical and/or biological issues. The Kubios software is one of the most used software to process HRV recordings, offering different levels of threshold-based artefact correction (i.e., Kubios filters). The aim of the study was to analyze the impact of different Kubios filters on the quantification of HRV derived parameters from short-term recordings in three independent human cohorts. A total of 312 participants were included: 107 children with overweight/obesity (10.0 ± 1.1 years, 58% men), 132 young adults (22.2 ± 2.2 years, 33% men) and 73 middle-aged adults (53.6 ± 5.2 years, 48% men). HRV was assessed using a heart rate monitor during 10–15 min, and the Kubios software was used for HRV data processing using all the Kubios filters available (i.e., 6). Repeated-measures analysis of variance indicated significant differences in HRV derived parameters in the time-domain (all p < 0.001) across the Kubios filters in all cohorts, moreover similar results were observed in the frequency-domain. When comparing two extreme Kubios filters, these statistical differences could be clinically relevant, e.g. more than 10 ms in the standard deviation of all normal R-R intervals (SDNN). In conclusion, the results of the present study suggest that the application of different Kubios filters had a significant impact on HRV derived parameters obtained from short-term recordings in both time and frequency-domains. ; The study was funded by the Spanish Ministry of Economy and Competitiveness (DEP2013-47540 and DEP2016-79512-R), the Fondo de Investigación Sanitaria del Instituto de Salud Carlos III (PI13/01393), European Union Development Funds, the Fundación Iberoamericana de Nutrición (FINUT), the Redes Temáticas de Investigación Cooperativa RETIC (Red SAMID RD16/0022), the University of Granada Plan Propio de Investigación 2016 (Excellence actions: Unit of Excellence on Exercise and Health [UCEES]), and the Junta de Andalucía, Consejería de Conocimiento, Investigación y Universidades (FEDER: ref. SOMM17/6107/UGR).

Problem melden

Wenn Sie Probleme mit dem Zugriff auf einen gefundenen Titel haben, können Sie sich über dieses Formular gern an uns wenden. Schreiben Sie uns hierüber auch gern, wenn Ihnen Fehler in der Titelanzeige aufgefallen sind.