Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units ; Der Nachweis aerober heterotropher Bakterien ist kein Prädiktor für eine Kontamination von Dentaleinheiten mit potentiellen Pathogenen

Abstract

Background: Currently, to our knowledge, quality of output water of dental chair units is not covered by specific regulations in the European Union, and national recommendations are heterogeneous. In Germany, water used in dental chair units must follow drinking water quality. In the United States of America, testing for aerobic heterotrophic bacteria is recommended. The present study was performed to evaluate whether the counts of aerobic heterotrophic bacteria correlate with the presence of potentially pathogenic bacteria such as Legionella spp. or Pseudomonas aeruginosa. Methods: 71 samples were collected from 26 dental chair units with integrated disinfection device and 31 samples from 15 outlets of the water distribution pipework within the department were examined. Samples were tested for aerobic heterotrophic bacteria at 35°C and 22°C using different culture media and for Legionella spp. and for Pseudomonas aeruginosa . Additionally, strains of Legionella pneumophila serogroup 1 were typed with monoclonal antibodies and representative samples of Legionella pneumophila serogroup 1 were typed by sequence based typing.Results: Our results showed a correlation between different agars for aerobic heterotrophic bacteria but no correlation for the count of aerobic heterotrophic bacteria and the presence of Legionella spp. or Pseudomonas aeruginosa. Conclusion: Testing for aerobic heterotrophic bacteria in output water or water distribution pipework within the departments alone is without any value for predicting whether the water is contaminated with potentially pathogenic bacteria like Legionella spp. or Pseudomonas aeruginosa. ; Hintergrund: Entsprechend unserer Kenntnis sind die Anforderungen an austretendes Wasser in Wasser führenden Elementen von Dentaleinheiten in keiner Europäischen Richtlinie geregelt. Nationale Empfehlungen sind heterogen. In Deutschland muss in Detaleinheiten eingespeistes Wasser der Trinkwasserverordnung entsprechen. In den Vereinigten Staaten wird die Überprüfung auf aerobe ...

Problem melden

Wenn Sie Probleme mit dem Zugriff auf einen gefundenen Titel haben, können Sie sich über dieses Formular gern an uns wenden. Schreiben Sie uns hierüber auch gern, wenn Ihnen Fehler in der Titelanzeige aufgefallen sind.